Based on the WaterSens solution using Opsens Solutions’ fiber-optic pressure sensors to measure water levels, the sensors, specially designed and adapted for fuel tanks, provide highly accurate, reliable and safe measurement. With no drift over time and no need for maintenance or calibration, the sensors are truly Plug & Forget.
The measurement principle is simple: the liquid level is calculated from the hydrostatic pressure, which corresponds to the thrust exerted by the height of the liquid due to the force of gravity. This pressure is determined using a unique, patented technology based on Fabry-Pérot optical interferometry. This technology, known as WLPI (White Light Polarization Interferometry), is based on phase modulation of light, the most sensitive method for fiber optic measurement.
Fully dielectric, this technology makes the sensors intrinsically safe and allows them to be deployed in explosive environments (ATEX).
This measurement solution is so reliable that it will be used in the next generation of aircraft to measure critical parameters such as fuel level.
Benefits
Maintenance free
- Plug & Forget sensing solutions
- Sensor doesn’t drift over time
- Designed to last decades
- No replacement/repair due to lightning because of its immunity to any electromagnetic interferences
Peace of Mind
- Integrated optical temperature sensor for real-time compensation
- Ideal for permanent installation in difficult-to-access tanks and vessels
- Out of the reservoir sensor
- Intrinsically safe (according to IEC 60079-28)
Applications
- LNG tank instrumentation
- Level measurement in storage tanks
- Compatible with all types of explosive fluids (fuel oil, LNG, hydrogen…)
- Aircraft fuel level measurement
PRESSURE SENSOR SPECIFICATIONS |
|
Measuring range - meter of liquid (other range available on request) | From 2 to 100 |
Accuracy (% F.S.) | ± 0.1 (at 22 °C) |
Precision (% F.S.) | ± 0.07 (at 22 °C) |
Thermal shift (% F.S./°C) | < ± 0.01 (measured between 10 and 60 °C) |
Operating Temperature (°C) | -40 to 70 (contact Sales for higher temperature) |
EMI/RFI Lightning | Complete immunity |
Housing | Stainless steel |
Cable sheathing | From ruggedized flexible outdoor cable to robust stainless-steel cable |
Cable length | Up to 3 km (sampling rate dependent, consult factory for more details) |
Signal conditioner compatibility | All Opsens Solutions’ WLPI conditioners |
TEMPERATURE SENSOR SPECIFICATIONS |
|
Accuracy (°C) | ± 1.0 (from -10 to 85 °C) |
Resolution (°C) | ± 0.01 |
Opsens Solutions Inc. reserves the right to make any changes to the above specifications without prior notice.
Do you need help to find your optic level sensor ?